GE_Security_NX_1448E_48_Zone_Fixed_LCD_Keypad_USED_01_qe

GE Security NX-1448E 48 Zone Fixed LCD Keypad USED

GE Security NX-1448E 48 Zone Fixed LCD Keypad USED
GE Security NX-1448E 48 Zone Fixed LCD Keypad USED
GE Security NX-1448E 48 Zone Fixed LCD Keypad USED
GE Security NX-1448E 48 Zone Fixed LCD Keypad USED

GE Security NX-1448E 48 Zone Fixed LCD Keypad USED
Enhance your home security with this GE Security CADDX NX-1448E 48 Zone Fixed LCD Keypad. Compatible with ADT, Interlogix, GE Security, and Caddx, this wired keypad provides easy and convenient control over your security system. The sleek white design complements any home decor, while the keypad’s features include 48-zone control and LCD display for easy use. This pre-owned NX-1448E model is in excellent working condition and perfect for anyone looking to upgrade their home security. With its user-friendly interface and reliable performance, you can have peace of mind knowing your home is protected. Order yours today and take the first step in securing your home.
GE Security NX-1448E 48 Zone Fixed LCD Keypad USED
Interlogix_CADDX_GE_Security_NX_200_NetworX_Zone_Doubling_Resistor_Kit_Expander_01_ldwl

Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander

Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander

Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
This is for ONE NX-200 Zone Doubling Resistor Kit for NetworX Series Panels. Zone Doubling Resistor Kit allows doubling of the panel’s on-board hardwire capacity. Includes (100) 3.74 K and (100) 6.98 K Ohm. Compatible with Alarm Control Panels by Interlogix /UTC & General Electric (GE) & CADDX NetworX Series Alarm Control Panels Including. NX-4, NX-6, NX-8 & NX-8E. GE & CADDX is Now. UTC Fire & Safety Interlogix. GE NetworX Intrusion & Property Protection Systems. The NX-200 is a zone doubling resistor kit from Interlogix which is designed to allow the number of zones on certain types of NetworX control panels to be doubled with certain restrictions depending on the particular control panel used. The NX-200 doubling resistor kit comes with (100) 3.74 Ohms, and (100) 6.98 Ohm resistors. WHEN USED WITH NX8 / NX8E CONTROL PANELS This feature allows you to use the eight zones on the panel as sixteen normally closed zones. When this feature is used European double E. Configuration cannot be used on the first sixteen zones. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 48. If one of the sixteen zones must be a fire zone, it must be one of zones 1 to 8. The corresponding upper zone will become unavailable. For example, if zone 6 is a fire zone, then zone 14 will not be available. WHEN USED WITH NX6 CONTROL PANELS This feature allows you to use the six zones on the panel as twelve normally closed zones. When this feature is used, zone seven cannot be a two-wire smoke zone, and European double E. Configuration cannot be used. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 16. Zones 7 – 12 should not be programmed as “Fire” zone types when Zone Doubling is used. If one of the twelve zones must be a fire zone, it must be one of zones 1 to 6. For example, if zone 6 is a fire zone, then zone 12 will not be available. WHEN USED WITH NX4 CONTROL PANELS Zone doubling can only be enabled when at least one other device is added to the basic system (consisting of the main control panel and one keypad). Additional devices can include wireless receivers, extra keypads, etc. If enabled, this feature allows you to use the four zones on the panel as eight normally closed zones. When this feature is used, European double E. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 8. If one of the eight zones must be a fire zone, it must be one of zones 1 – 4. For example, if zone 4 is a fire zone, then zone 8 will not be available. REFER TO PROGRAMMING LOCATION 37 IN THE INSTALLATION MANUALS FOR FURTHER INSTRUCTIONS. Please request an invoice before paying if combining with items from our other listings.
Interlogix CADDX GE Security NX-200 NetworX Zone Doubling Resistor Kit Expander
DSC_PC1500RK_6_Zone_Keypad_for_Classic_Series_PC1500_PC1550_NEW_01_we

DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW

DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW
DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW
DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW
DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW
DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW

DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW
DSC PC1500RK Digital LED Keypad. Guaranteed not to be Dead on Arrival. RARE & HARD TO FIND.. And yes REALLY NEW & UNUSED! ONLY For the DSC Classic Series Panels: PC1500 & PC1550. Classic Series Alarm Control Panels. Please ask if you have questions about compatibility concerns with other DSC vintage security equipment. I’m glad to give you some viable options to try help keep your system up and running. DSC PC1500RK 6 Zone Keypad. Compatible with DSC Classic Series PC1500 & PC1550 Control Panels. This is New old stock that has been sitting on the shelves for several years. These have not been manufactured for quite some time. Your satisfaction is guaranteed. If we made a mistake, then the S&H is on us. Please request an invoice before paying if combining with items from our other listings.
DSC PC1500RK 6 Zone Keypad for Classic Series PC1500 & PC1550 NEW