Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT

Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT

Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT
Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT
Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT

Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT
Brand New Honeywell TSSC Wireless Pulse Panel and Alpha Keypad, w/ GSM. Works with all Honeywell 5800 series Wireless items. The TS ADT developed will solve some issues, but the greatest of them is the installation time to install an ADT Pulse Premier monitored customer. (The ability to control lights, thermostats, doorlocks, cameras, and now even garage doors). Currently an ADT iHub and an HSPIM (bridge) is needed to connect the alarm panel and provide the additional features of video and automation. The TS panel has the alarm panel and iHub built into one. Features of the ADT TS Panel. Capable of 250 Wireless Devices (alarm equipment and z-wave devices combined up to 140 z-wave and up to 250 wireless devices like door sensors, window sensors, motion detectors, etc). 10,000 event memory. Currently the control panel options ADT has available have a capacity of 40-64 zones. 250 is an unprecedented amount that puts it ahead of any other wireless alarm panel of its kind on the market. The current iHub has a capacity of 10 cameras, so this expands on that to 16. Most other cloud services with competitors can only handle 4-6 cameras and they limit the amount of recording. ADT Pulse is the only service that allows unlimited 30 second clips for a month. (regardless of the size of the data) User codes and keypad capacity is also blowing away competition. The kit comes with. (1) TSSC Base Station. The TSSC-BASE is a wireless Control Unit that allows you to perform system arming and disarming functions, as well as to monitor the status of your security system. (1) TSSC Alpha Keypad. The TSSC-KP is a wireless keypad that allows you to perform your security system functions, as well as to display the status of your security system. (2) Back batteries for base and alpha keypad. (2) Transformers for base and alpha keypad. (1) TS Keypad Wall Mount Plate. Keys on the TSSC Base Station and the TSSC Keypad. OFF Disarms the system, silences alarms and troubles, and helps clear troubles. You need to type your code in first then push 1(OFF). AWAY Arms perimeter and interior burglary protection. (The motion detector is on when you arm this way) If you arm this way and do not open a door it will switch to stay mode. STAY Arms the perimeter and not the motion detector. NIGHT STAY Additional mode for staying in the premises. You can create a third way of arming with this without having a delay like usual if you wanted. MAX Arms in Away mode but eliminates the entry delay. TEST (Keypad only) Tests the system and the siren if disarmed. BYPASS (Keypad only) Lets you arm the system without arming selected zones. If you have a zone that is not working properly you can still arm it if you bypass it. Also if you want to leave a window open for a night you can bypass it. INSTANT Arms like stay mode but eliminates the entry delay. Alarm will sound immediately if someone opens an entry zone. (Keypad only) Lets you assign user codes or change the master code. CHIME (Keypad only) Lets you turn the chime on and off. READY (Keypad Only) This displays all open zones. Also if you hold it zone for 5 seconds it will display all zone descriptions. # (Keypad only) Lets you arm the system without using a security code. (push # stay or # away for example). Police, Fire, and other special function keys (keypad only) Push these panic buttons if there is an emergency. You can program the other two for custom operations. How to get the system status of your TSSC System. If a customer calls in with an issue the first thing we have them do is go to the keypad and push the button so they can tell us what they see. How do I arm my ADT TSSC System? You can arm the system in AWAY, STAY, INSTANT, or MAX mode just by typing in your 4-digit code and pressing the corresponding button. If your quick arm is enabled you can press # and then one of the arming modes above. How do I DISARM the system? To disarm the system enter your code and press OFF. (OFF is the 1 key). How do I Bypass a zone? You can either bypass one zone at a time or up to five at a time. You just need to enter your code, then press 6 (the BYPASS key), and then the 3 digit number of the zone you want bypassed. Examples: user code + 6 + 002. Or usercode + 6 + 003 004 005 006 007. If your forced bypass is enabled you can also bypass all faulted zones by typing in your user code + 6 + # + 0. How do I change the master code? The installer will sometimes leave the default user code in the system and he might tell you how to change it but then after he leaves you forget. You just need to type in the master code + 801+ new user code twice. How do I add a user? This is the best thing to do if multiple people use the alarm or if you dont want to give out your master code to someone. Just type in your master code + 8 + 2 digit user number (02-96) + 4 digit new users code. How do I delete a user? Enter the mastercode + 8 + 2 digit user number you want to delete + # + 0. Authority Levels You can also add users and secondary codes but not give them the same authority. There are 4 levels you can give them. 0 Standard user Can perform security functions but not the ones reserved for the master user. 1 Arm Only user Can only arm the system, cannot disarm. 2 Guest Can arm, bypass zones, but can only disarm if they are the one that armed the system. Example: for a babysitter or cleaner where they only need to arm or disarm at certain times. 3 Duress Code This is intended to be used if a person is forced to disarm the system under threat. When used the system will act normally but silently send a notification to the ADT Monitoring Station of the situation. (this feature may not be activated if you did not specifically ask for it). To assign authority you type in the master code + 8 + 2 digit user number + # + 1 + single digit authority level. Chime Mode This feature allows you to turn on or off the alert sound if a door or window is opened. You can activate it while it is disarmed by typing your code and pushing the CHIME key (9). You can turn it off by doing the same steps. My Alarm/Keypad keeps beeping? If it is really the keypad beeping (and not a non-ADT smoke detector, etc) then pushing will tell you why and also stop the beeping. Host Check-In If you see Download Com/Upload completed it is because the system is checking in with the ADT Central Station. It can do this every 200 seconds. (if the interval is set to 200 seconds). Test Mode Use test mode to check each protection point for proper operation. Testing is recommended to be done weekly. These are the steps to test. The keypad will beep every 60 seconds as a reminder that you are in test mode. Alarm messages are not sent to ADT while you are in the test mode. If you have a problem with any of the zones please call ADT for service immediately. If you leave it in test mode it will automatically exit test mode after 30 minutes. Disarm the system and close all doors and windows. Enter the master code + 5 (that is the test button) + then press 1. The siren should sound for 1 second then turn off. Fault all zones in turn and listen for three beeps from the keypad. (Fault means for you to open each one) Each time you open a window or door the zone number and description should appear on the keypad. The display clears when a zone is closed. If you are testing a wireless motion detector there is a 3 minute delay between activations to conserve battery power. Test all smoke and CO detectors following the manufacturers instructions and check the display. When all zones have been checked and are intact (closed), there should be no zone identification numbers on the keypad. Exit test mode by typing your code + OFF (the 1 key). The item “Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT” is in sale since Wednesday, December 07, 2016. This item is in the category “Home & Garden\Home Improvement\Home Security\Security Keypads”. The seller is “leebruce777″ and is located in Norfolk, Virginia. This item can be shipped to United States, to Canada, to United Kingdom, DK, RO, SK, BG, CZ, FI, HU, LV, LT, MT, EE, to Australia, GR, PT, CY, SI, to Japan, to China, SE, KR, ID, to Taiwan, ZA, TH, to Belgium, to France, to Hong Kong, to Ireland, to Netherlands, PL, to Spain, to Italy, to Germany, to Austria, RU, IL, to Mexico, to New Zealand, PH, SG, to Switzerland, NO, SA, UA, AE, QA, KW, BH, HR, MY, BR, CL, CO, CR, PA, TT, GT, HN, JM.
  • Brand: Honeywell

Honeywell TSSC Wireless Pulse Panel TSSPK111251U and Alpha Keypad WORKING ADT